Digital Thermometer and Thermostat
_______________________________________________________________________________________   3
Note 1:   All voltages are referenced to ground.
Note 2:   Internal heating caused by O.S. loading causes the DS7505 to read approximately 0.5?/SPAN>C higher if O.S. is sinking the
max-rated current.
Note 3:   Specified in 12-bit conversion mode. Quantization error must be considered when converting in lower resolutions.
Note 4:   I
DD
specified with O.S. pin open.
Note 5:   I
DD
specified with V
DD
at 3.0V and SDA, SCL = 3.0V, T
A
= -55癈 to +85癈.
Note 6:   I
DD
specified with A0, A1, A2 = 0V or V
DD
.
Note 7:   V
DD
must be > 2.0V.
Note 8:   E
2
Copy occurs at +25癈.
Note 9:   See the timing diagram (Figure 1). All timing is referenced to 0.9 x V
DD
and 0.1 x V
DD
.
Note 10:  After this period, the first clock pulse is generated.
Note 11:  The DS7505 provides an internal hold time of at least 75ns on the SDA signal to bridge the undefined region of SCLs
falling edge.
Note 12:  For example, if C
B
= 300pF, then t
R(MIN)
= t
F(MIN)
= 50ns.
Note 13:  This timeout applies only when the DS7505 is holding SDA low. Other devices can hold SDA low indefinitely and the
DS7505 does not reset.
AC ELECTRICAL CHARACTERISTICS (continued)
(1.7V d V
DD
d 3.7V, T
A
= -55癈 to +125癈, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
EEPROM Data Retention
t
EEDR
 
-40癈 to +125癈 (Note 8)
10
 
 
Years
Bus Free Time Between a STOP
and START Condition
t
BUF
 
(Note 9)
1.3
 
 
START and Repeated START
Hold Time from Falling SCL
t
HD:STA
(Notes 9, 10)
600
 
 
ns
Low Period of SCL
t
LOW
 
(Note 9)
1.3
 
 
High Period of SCL
t
HIGH
 
(Note 9)
0.6
 
 
Repeated START Condition
Setup Time to Rising SCL
t
SU:STA
(Note 9)
600
 
 
ns
Data-Out Hold Time from Falling
SCL
t
HD:DAT
(Notes 9, 11)
0
 
0.9
Data-In Setup Time to Rising
t
SU:DAT
(Note 9)
100
 
 
ns
Rise Time of SDA and SCL
(Receive)
t
R
 
(Notes 9, 12)
20 +
0.1C
B
300
ns
Fall Time of SDA and SCL
(Receive)
t
F
 
(Notes 9, 12)
20 +
0.1C
B
 
300
ns
Spike Suppression Filter Time
(Deglitch Filter)
t
SS
 
 
0
 
50
ns
STOP Setup Time to Rising SCL
t
SU:STO
(Note 9)
600
 
 
ns
Capacitive Load for Each Bus
Line
C
B
 
 
 
 
400
pF
Input Capacitance
C
I
 
 
 
5
 
pF
Serial Interface Reset Time
t
TIMEOUT
    SDA time low (Note 13)
75
 
325
ms
相关PDF资料
DS75LVU+T&R IC SENSOR TEMP DIGITAL 8MSOP
DS75LXS+ IC THERMOMETER/STAT DIG 8-SOIC
DS75U+T&R IC THERMOMETER/STAT DIG 8-MSOP
FAN4010IL6X_F113 IC CURRENT SENSE 0.2% 6MLP
FAN5069EMTCX IC REG DL BCK/LINEAR 16TSSOP
HIP1011BCB-T IC CTRLR HOT PLUG PCI 16-SOIC
HIP1020CK-T IC CTRLR HOT PLUG SOT23-5
HIP6018BCBZ-T IC REG TRPL BCK/LINEAR 24-SOIC
相关代理商/技术参数
DS7505UR 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:Digital Thermometer and Thermostat
DS7505UT 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:Digital Thermometer and Thermostat
DS75-08B 功能描述:整流器 75 Amps 800V RoHS:否 制造商:Vishay Semiconductors 产品:Standard Recovery Rectifiers 配置: 反向电压:100 V 正向电压下降: 恢复时间:1.2 us 正向连续电流:2 A 最大浪涌电流:35 A 反向电流 IR:5 uA 安装风格:SMD/SMT 封装 / 箱体:DO-221AC 封装:Reel
DS750PED-3 功能描述:线性和开关式电源 12V output 750W Platinum RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
DS750PED-3-001 制造商:Emerson Network Power - Embedded Power 功能描述:12V OUTPUT, 750W 1U X 3.4 X 7.8 PLATINUM WITH REVERSE AIR - Bulk 制造商:ARTESYN EMBEDDED TECHNOLOGIES 功能描述:AC/DC CONVERTER 12V 12V 750W 制造商:Emerson Embedded Power 功能描述:AC/DC CONVERTER 12V 12V 750W 制造商:Emerson Network Power - Embedded Power 功能描述:12V output, 750W 1U x 3.4 x 7.8 Platinum with reverse air
DS750PED-3-402 制造商:Emerson Network Power - Embedded Power 功能描述:- Bulk
DS750PED-3-403 制造商:Emerson Network Power - Embedded Power 功能描述:12V OUTPUT, 750W 1U X 3.4 X 7.8 PLATINUM WITH REVERSE AIR - Bulk
DS75107 制造商:NSC 制造商全称:National Semiconductor 功能描述:Dual Line Receiver